Control Panel Potter IPA-60

The IPA-60 is an analog/addressable releasing fire alarm system with a total system capacity of 60 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC).

The IPA-60 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The I/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously.

The IPA-60 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN-1000 may be used to extend releasing capability. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the IPA-60 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN1000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections.
Feature:
» 60 addresses available on this analog addressable system
» Additional system capacity achieved via multi-point SLC modules
» 99 software zones
» NFPA 72 Compliant Smoke Sensitivity Test Built-In
» System Operates as Class A or Class B for SLC, P-Link and NACs
» 5 Amp Power Supply, Expandable to 310 amps
» 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188
» 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each, ideal for manual release and abort
» Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes
» Dedicated Alarm, Supervisory and Trouble Relays
» 4,000 Event History Buffer
» Cabinet will house up to 18 AH batteries
» Optional two line DACT with UD-2000 that can report General, Zone or Point Information
» Built in IP Communicator
» Ethernet Port for Programming and Network Connectivity
» E-Mail System Status, Reports and Event Information
» Product includes 5 year warranty
» UUKL Listed for Smoke Control
Specification:
» Dimensions : 16”W x 17”H x 3 7/8”D
» AC Mains : 3.0 Amps @ 120 VAC 50/60 HZ, 2.0 Amps @ 240 VAC 50/60 HZ
» Enclosure : 16 gauge cold rolled steel with removable locked door with Lexan viewing window
» Battery : Standby Current-130 mA, Alarm Current-200 mA
- 5 Amps power for NACs, I/O, and P-Link
- 3 Amps per NAC, regulated
- 1 Amp per I/O circuit, regulated
- Battery Charger range 8-55 Ah
- Battery Charger voltage 27.3 VDC
- P-Link maximum current of 1 Amp
» Temperature and Humidity Range : 32° to 120° (0°C to 49°C) with a maximum humidity of 93% non-condensing
» Standards :
- NFPA 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 92, 750, and 2001
- ANSI/UL 864 - Local (L), Remote Station (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Automatic (A), Manual (M), Water flow (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev Pol), Other Technologies (OT)
- IBC (International Building Code)